Thermal Mass Flow Meter

Thermal gas mass flow meter measuring principle is the use of heat conduction flow meter. The meter use constant difference in temperature method for accurate measurement of gas mass flow, it has the advantages of small volume, high digitization, easy installation, high accuracy .etc Sensor portion consists of two reference level platinum resistance temperature sensor, using bridge circuit, one for measuring temperature, the other for maintaining the constant different in temperature which higher than fluid temperature, it could apply to measuring flow under high temperature and pressure.

  • 型号: TNF-TMF

图片关键词

图片关键词

图片关键词

Technical data:

 

Measuring medium

All gas(except Acetylene gas)

Pipe range

DN10~100mm(Full pipe)

DN80~6000mm(Insertion)

Flow range

0.5~100Nm/s

Accuracy

±1%

Working temperature

Transducer: Normal:-10°C~+200°C, 

high temp: -10°C~+350°C   Converter: -20°C~+45°C

Working pressure

Medium≤10Mpa

Medium pressure≤2.5Mpa

Power supply

Compact type(DC24V or AC220V ≤18W) Split type(AC220V ≤19W)

Signal output

4-20mA(Optoelectronic isolation, upload 500Ω), 

RS485(Optoelectronic isolation), Hart protocol

Pipe material

Carbon steel, SS, plastic .etc

Display

Compact type: 4 lines LCD display

Display contents

Mass flow, standard volume flow, accumulated flow,

 standard time, accumulated working time, 

medium temperature, standard flow rate .etc

Protection

IP67

Sensor material 

SS

SS, Carbon steel